Command Line Interface Guide

NOTE: Power Management features are only available for PowerEdge systems that have hot-swappable power
supplies and not systems that have a fixed, non-redundant power supply installed.
Omreport Chassis Pwrsupplies Or Omreport Mainsystem Pwrsupplies
Use the omreport chassis pwrsupplies or omreport mainsystem pwrsupplies command to view properties of the
system’s power supplies. Type:
omreport chassis pwrsupplies
or
omreport mainsystem pwrsupplies
NOTE: To maintain consistency across the commands, the output format of this command has changed. Change
the user scripts as applicable.
For each power supply profile in the system, values display for the following fields:
Status
Location
Type
Rated Input Wattage (in Watts)
Maximum Output Wattage
Online Status
Power Monitoring Capable
Omreport Chassis Remoteaccess Or Omreport Mainsystem Remoteaccess
Use the omreport chassis remoteaccess or omreport mainsystem remoteaccess command to view general information
on baseboard management controller or integrated Dell remote access controller (BMC/iDRAC) and remote access
controller if DRAC is installed. Type:
omreport chassis remoteaccess
or
omreport mainsystem remoteaccess
NOTE: To maintain consistency across the commands, the output format of this command and the subsequent
command levels has changed. So, you may have to change the user scripts as applicable.
The output of the omreport chassis remoteaccess or omreport mainsystem remoteaccess command lists each of the
valid parameters as displayed in the following table:
Table 12. Valid Parameters Of Omreport Chassis Remoteaccess Or Omreport Mainsystem Remoteaccess
name=value pair Description
config=additional Reports the current state of IPv4 and IPv6 addresses on iDRAC.
config=advsol Reports advanced BMC/iDRAC or remote access information on a serial over local area
network (LAN) connection.
config=nic Reports BMC/iDRAC or remote access information for the LAN.
config=serial Reports serial port information for BMC or remote access.
41