Field Description
In a write-through policy, the processor writes through the cache to the main
memory. The write cycle does not complete until the data is stored into the main
memory.
Associativity
Refers to the way in which main memory content is stored on the cache.
• A fully associative cache allows any line in main memory to store at any
location in the cache.
• A
n
-way set-associative cache directly maps
n
specific lines of memory to
the same
n
lines of cache. For example, line 0 of any page in memory is
stored in line 0 of cache memory.
Cache Device Supported Type Type of static random access memory (SRAM) that the device can support.
Cache Device Current Type Type of the currently installed SRAM that the cache is supporting.
External Socket Name Silk Screen
Name
Name printed on the system board next to the socket.
Error Correction Type Identifies the type of error checking and correction (ECC) that this memory can
perform. Examples are correctable ECC or uncorrectable ECC.
Omreport Chassis Pwrmanagement Or Omreport Mainsystem Pwrmanagement
Use the omreport chassis pwrmanagement or omreport mainsystem pwrmanagement command to view the power
budget cap and power management profiles of the system. The values display either in Watts or BTU/Hr based on the
configuration. Type:
omreport chassis pwrmanagement
or
omreport mainsystem pwrmanagement
NOTE: To maintain consistency across the commands, the output format of this command and the subsequent
command levels has changed. So, you may have to change the user scripts as applicable.
NOTE: The omreport chassis pwrmanagement or omreport mainsystem pwrmanagement command is applicable
on PowerEdge 11G systems that support Power Management Bus (PMBus) and that have hot-swappable power
supplies and not systems that have a fixed, non-redundant power supply installed.
The output of the omreport chassis pwrmanagement or omreport mainsystem pwrmanagement command lists each of
the valid parameters. The following table lists the available settings.
Table 11. Valid Parameters Of Omreport Chassis Pwrmanagement Or Omreport Mainsystem Pwrmanagement
name=value pair Description
unit=<watt | btuphr>
Displays power in the user-specified units.
config=budget
Displays power budget information.
config=profile
Displays power profiles information.
NOTE: On PowerEdge 12G systems, profile
option is SysProfile and is grouped under
System Profile Settings of the BIOS setup group. For
more information, see BIOS Setup Settings on
PowerEdge 12G systems.
38