Command Line Interface Guide
For RAID 10 on SAS controllers with firmware version 6.1 and later, spanlength is optional. Also, you can now specify the
spanlength as an even number with a maximum of 8 spans with 32 physical disks each. For example:
omconfig storage controller action=createvdisk controller=1 raid=r10 size=min
pdisk= 1:1:0,1:1:1,1:1:3,1:1:4,1:1:6,1:1:7,1:1:8,1:1:9
spanlength=4
Omconfig Set Controller Rebuild Rate
Description
Sets the controller rebuild rate.
Syntax
omconfig storage controller action=setrebuildrate controller=id
rate=<0 to 100>, where id is the controller ID as reported by the omreport storage controller
command.
Example to Set the rebuild rate to 50 on controller 1.
Example
omconfig storage controller action=setrebuildrate controller=1
rate=50
omconfig Change Controller Properties
Table 106. omconfig Change Controller Properties
Description
Changes any or all of the controller properties.
Syntax
omconfig storage controller action=
setchangecontrollerproperties
controller=<id> bgirate=<rate>
reconstructrate=<rate>
checkconsistencyrate=<rate>
rebuildrate=<rate>
clearredundantpath=clear
abortcheckconsistencyonerror=<enabled |
disabled> loadbalance=<auto | disabled>
allowrevertiblehotspareandreplacemember
=<enabled | disabled>
autoreplacememberonpredictivefailure=
<enabled | disabled>
persistenthotspare=<enabled | disabled>
Example to Enable allow revertible hot spare and replace member
operation.
Example
omconfig storage controller action=
setchangecontrollerproperties
allowrevertiblehotspare
andreplacemember=enabled controller=1
Omconfig Discard Preserved Cache
Description Discards the preserved cache on the controller.
NOTE: To check if the controller has a preserved cache, type omreport storage
controller controller=id. If the system displays Preserved Cache=yes, it
indicates the presence of the preserved cache.
Syntax
omconfig storage controller action= discardpreservedcache
controller=id force=enabled | disabled
167