Command Line Interface Guide

Omconfig Physical Disk Commands
The following sections provide the omconfig command syntax required to execute physical disk tasks
Table 87. Omconfig Physical Disk Commands
Required Command Levels (1, 2, 3) Optional name=value pairs
omconfig storage pdisk action=blink controller=id pdisk=<PDISKID>
action=unblink controller=id pdisk=<PDISKID>
action=remove controller=id pdisk=<PDISKID>
action=instantsecureerase controller=id pdisk=<PDISKID>
action=initialize controller=id pdisk=<PDISKID>
action=offline controller=id pdisk=<PDISKID>
action=online controller=id pdisk=<PDISKID>
action=assignglobalhotspare controller=id pdisk=<PDISKID> assign=<yes | no>
action=rebuild controller=id pdisk=<PDISKID>
action=cancelrebuild controller=id pdisk=<PDISKID>
action=cancelreplacemember controller=id pdisk=<PDISKID>
action=clear controller=id pdisk=<PDISKID>
action=cancelclear controller=id pdisk=<PDISKID>
action=enabledevicewritecache controller=id pdisk=<PDISKID>
action=disabledevicewritecache controller=id pdisk=<PDISKID>
action=exportreliabilitylog controller=id pdisk=<PDISKID>
action=convertraidtononraid controller=id pdisk=<PDISKID>
action=convertnonraidtoraid controller=id pdisk=<PDISKID>
Omconfig Blink Physical Disk
Description
Blinks the light (light emitting diode or LED display) on one
or more physical disks attached to a controller.
Syntax
omconfig storage pdisk action=blink
controller=id pdisk=<PDISKID>, where id is
the controller ID. The <PDISKID> variable specifies the
physical disk.
NOTE: To obtain these values, type omreport storage
controller to display the controller IDs and then type
omreport storage pdisk controller=ID to display the
IDs for the physical disks attached to the controller.
Example to Blink physical disk 0 on connector 0 of controller 1. On a
SAS controller, the physical disk resides in enclosure 2.
140