Command Line Interface Guide
or
omconfig servermodule recovery timer=120
Omconfig System Shutdown Or Omconfig Servermodule Shutdown
Use the omconfig system shutdown or omconfig servermodule shutdown command to determine the way in which the
system shuts down. During system shutdown, the default is to shut down the operating system before powering off the
system. Shutting down the operating system first closes down the file system before powering the system down. If you
do not want to shut down the operating system first, use the osfirst=false parameter. The following table displays the
valid parameters for the command.
NOTE: Due to the limitations of certain operating systems (for example, VMware ESXi), certain features are not
available with this release of OpenManage Server Administrator.
Table 50. Valid Parameters Of System Shutdown
name=value pair Description
action=reboot Shuts down the operating system and initiates system startup, performing BIOS checks and
reloading the operating system.
action=poweroff Turns off the electrical power to the system.
action=powercycle Turns off the electrical power to the system, pauses, turns the power on, and reboots the
system. Power cycling is useful when you want to re-initialize system components such as hard
drives.
osfirst=true | false
true: Closes the file system and exits the operating system before shutting down the system.
false: Does not close the file system or shut down the operating system before shutting down
the system.
Example Shutdown Commands
To set the shutdown action to reboot, type:
omconfig system shutdown action=reboot
or
omconfig servermodule shutdown action=reboot
To bypass operating system shutdown before the system is powered off, type:
omconfig system shutdown action=reboot osfirst=false
or
omconfig servermodule shutdown action=reboot osfirst=false
Omconfig System Thrmshutdown Or Omconfig Servermodule Thrmshutdown
Use the omconfig system thrmshutdown or omconfig servermodule thrmshutdown command to configure a thermal
shutdown action. You can configure the system for a thermal shutdown when a temperature probe detects a
temperature probe warning or failure event.
The following table displays the valid parameters for the command: