Command Line Interface Guide

name=value pair Description
type=systempower Configures events for system power.
type=temps Configures events for temperatures.
type=volts Configures events for voltages.
type=systempeakpower Configures events for system peak power.
type=removableflashmedia Configures events for removable flash media.
Severity
In the context of configuring events, severity determines how severe an event is, before Server Administrator notifies
you of the event for a component type. When there are multiple components of the same type in the same system
chassis, you can specify whether you want notification for event severity according to the number of the component by
using the index=<
n
> parameter. The following table displays the valid severity parameters.
Table 47. System Event Severity Parameters
Command Result Description
omconfig system events
type=<
component name
>
severity=info or omconfig
servermodule events
type=<
component name
>
severity=info
Enables notification for informational,
warning, and critical events.
Least restrictive form of event
notification.
omconfig system events
type=<
component name
>
severity=warning or omconfig
servermodule events
type=<
component name
>
severity=warning
Enables notification for warning and
critical events.
Omits informational event notification,
for example, when a component
returns to normal status.
omconfig system events
type=<
component name
>
severity=critical or omconfig
servermodule events
type=<
component name
>
severity=critical
Enables notification for critical events
only.
Restrictive form of event notification.
omconfig system events
type=<
component name
>
severity=none or omconfig
servermodule events
type=<
component name
>
severity=none
Disables event notification. No event notification.
Index
Index refers to the number of an event for a particular component. Index is an optional parameter. When you omit the
index parameter, events are configured for all components of the specified type, such as all fans. For example, when a
system contains more than one fan, you can enable or disable event notification for a particular fan. An example
command is as follows:
omconfig system events type=fan index=0 severity=critical
108