Command Line Interface Guide

The event is a power supply failure and the action is to broadcast a message to all Server Administrator users.
Available Alert Actions
The following table displays the alert actions for each component that allows you to configure an alert action:
Table 41. Valid Parameters of Alert Actions For Warning and Failure Events
Alert Action Setting Description
alert=true | false
true: Enables the system's console alert. When enabled,
the monitor attached to the system from which you are
running Server Administrator displays a visual alert
message.
false: Disables the system's console alert.
broadcast=true | false
true: Enables a message or alert to broadcast to all users
who have an active terminal (or Remote Desktop) session
(Windows) or to operators that have an active shell on the
local system (Linux.)
false: Disables alert broadcasts.
clearall=true Clears all actions for this event.
execappath=<string>
Sets the fully qualified path and file name of the
application you want to execute in case of an event for the
component described in this window.
NOTE: On Linux systems, user or user groups
upgraded to administrator or administrator groups
cannot configure this alert action setting.
execapp=false Disables the executable application.
Components And Events For Alert Actions
The following table provides the events for which you can set alert actions. Components are listed in alphabetical order,
except that warning events always precede failure events for a component.
Table 42. Valid Parameters Of Events for Alert Actions
Event Name Description
event=batterywarn Sets actions when a battery probe detects a warning value.
event=batteryfail Sets actions when a battery probe detects a failure value.
event=fanwarn Sets actions when a fan probe detects a warning value.
event=fanfail Sets actions when a fan probe detects a failure value.
event=hardwarelogwarn Sets actions when a hardware log detects a warning value.
event=hardwarelogfull Sets actions when a hardware log is full.
event=intrusion Sets actions when a chassis intrusion event is detected.
event=memprefail Sets actions when a memory probe detects a prefailure value.
event=memfail Sets actions when a memory probe detects a failure value.
event=systempeakpower Sets actions when a power consumption probe detects peak power value.
event=systempowerwarn Sets actions when a power consumption probe detects a warning value.
101