SNMP Reference Guide

TrapID Name Description Severity Category Cause Supporte
d by RAC
Platform
probe has
detected a
warning value
1014 alertDrscVolt Critical The RAC
voltage probe
has detected a
failure (or
critical) value
Critical Error RAC voltage probe reading
exceeded critical threshold.
DRAC III
1015 alertDrscSEL Warning The
RAC has
detected a new
event in the
System Event
Log with
Severity:
Warning
Major Error RAC detected a new system
event log with warning
severity (detailed log info is in
drsAlert Message varbind).
All
1016 alertDrscSEL Critical The RAC
has detected a
new event in the
System Event
Log with
Severity: Critical
Critical Error RAC detected a new system
event log with critical
severity (detailed log info is in
drsAlert Message varbind).
All
1017 alertDrscSEL
80 percentFull
The RAC system
event log is 80%
full
Major Status RAC detected system event
log is 80% full.
All
1018 alertDrscSEL
90 percentFull
The RAC system
event log is 90%
full
Major Status RAC detected system event
log is 90% full.
All
1018 alertDrscSEL
90 percentFull
The RAC system
event log is 90%
full
Major Status RAC detected system event
log is 90% full.
All
1020 alertDrscSEL
Normal
The RAC has
detected a new
event in the
System Event
Log with
Severity: Normal
Information Error RAC detected a new system
event log with normal
severity (detailed log info is in
drsAlert Message varbind).
All
BMC Traps
The BMC monitors the system for critical events by communicating with various sensors on the system board and by
sending alerts and log events when certain parameters exceed their preset thresholds. All of the traps documented in
this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.3183.1.1.1.
534