SNMP Reference Guide
TrapID Name Description Severity Category Cause Supporte
d by RAC
Platform
1006 alertDrscPow
er On
The RAC has
detected a
system power
state change to
powered-on
Information Error RAC detected a system
power state change to
power-on.
DRAC III
1007 alertDrsc Watchdog
Expired The RAC
has detected
that the system
watchdog has
expired
indicating a
system hang
Critical Event RAC has detected the system
watchdog expired (normally
indicating a system hang).
DRAC III
1008 alertDrscBatt
Low
The RAC Battery
charge is below
25% indicating
that the battery
may only be
able to power
the DRSC for 8-
10 minutes
Minor Error RAC detected its battery
charge is below 25% full.
DRAC III
1009 alertDrscTem
p
Normal The RAC
Temperature
probe has
returned to a
normal value
Information Status RAC temperature probe
reading returned to normal.
DRAC III
1010 alertDrscTem
p
Warning The
RAC
Temperature
probe has
detected a
Warning value
Minor Status RAC temperature probe
reading exceeded warning
threshold.
DRAC III
1011 alertDrscTem
p
Critical The RAC
Temperature
probe has
detected a
failure (or
critical) value
Critical Error RAC temperature probe
reading exceeded critical
threshold.
DRAC III
1012 alertDrscVolt Normal The RAC
voltage has
returned to a
normal value
Information Error RAC voltage probe reading
returns to normal.
DRAC III
1013 alertDrscVolt Warning The
RAC voltage
Minor Error RAC voltage probe reading
exceeded warning threshold.
DRAC III
533