SNMP Reference Guide
Description Defines the index (one-based) of the associated chassis.
Syntax DellCMCPowerIndexRange
Access Read-only
Table 1946. DRsPSUIndex
Name
DRsPSUIndex
Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.2
Description Defines the index (one-based) of the associated CMC PSU.
Syntax DellCMCPSUIndexRange
Access Read-only
Table 1947. DRsPSULocation
Name
DRsPSULocation
Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.3
Description Defines the location of the CMC PSU.
Syntax DellString
Access Read-only
Table 1948. DRsPSUMonitoringCapable
Name
DRsPSUMonitoringCapable
Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.4
Description Defines the PSU Monitoring capabilities, or the absence of a PSU in this location.
Syntax DellCMCPSUCapable
Access Read-only
Table 1949. DRsPSUVoltsReading
Name
DRsPSUVoltsReading
Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.5
Description Defines the instantaneous PSU Voltage reading.
Syntax DellPowerReading
Access Read-only
Table 1950. DRsPSUAmpsReading
Name
DRsPSUAmpsReading
Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.6
Description Defines the instantaneous PSU Current reading.
Syntax DellPowerReading
Access Read-only
522