Reference Guide

Tabla 82. Comandos de disco físico omconfig
Niveles de comando requeridos (1, 2,
3)
Pares nombre=valor opcionales
omconfig storage pdisk action=blink controller=id pdisk=<PDISKID>
action=unblink controller=id pdisk=<PDISKID>
action=remove controller=id pdisk=<PDISKID>
action=instantsecureerase controller=id pdisk=<PDISKID>
action=initialize controller=id pdisk=<PDISKID>
action=offline controller=id pdisk=<PDISKID>
action=online controller=id pdisk=<PDISKID>
action=assignglobalhotspare controller=id pdisk=<PDISKID> assign=<yes | no>
action=rebuild controller=id pdisk=<PDISKID>
action=cancelrebuild controller=id pdisk=<PDISKID>
action=cancelreplacemember controller=id pdisk=<PDISKID>
action=clear controller=id pdisk=<PDISKID>
action=cancelclear controller=id pdisk=<PDISKID>
action=enabledevicewritecache controller=id pdisk=<PDISKID>
action=disabledevicewritecache controller=id pdisk=<PDISKID>
action=exportreliabilitylog controller=id pdisk=<PDISKID>
action=convertraidtononraid controller=id pdisk=<PDISKID>
action=convertnonraidtoraid controller=id pdisk=<PDISKID>
Hacer parpadear un disco físico omconfig
Descripción
Hace parpadear la luz (el diodo emisor de luz o LED) en
uno o más de los discos físicos conectados a una
controladora.
Sintaxis
omconfig storage pdisk action=blink
controller=id pdisk=<PDISKID>, donde id es la
identificación de la controladora. La variable <PDISKID>
especifica el disco físico.
NOTA: Para obtener estos valores, escriba omreport
storage controller para mostrar las identificaciones
de las controladoras y, a continuación, escriba
omreport storage pdisk controller=ID para mostrar las
identificaciones de los discos físicos conectados a la
controladora.
Ejemplo de acción Haga parpadear el disco físico 0 en el conector 0 de la
controladora 1. En una controladora SAS, el disco físico
reside en el gabinete 2.
144