Reference Guide

Table 82. Omconfig Physical Disk Commands
Required Command Levels (1, 2, 3) Optional name=value pairs
omconfig storage pdisk action=blink controller=id pdisk=<PDISKID>
action=unblink controller=id pdisk=<PDISKID>
action=remove controller=id pdisk=<PDISKID>
action=instantsecureerase controller=id pdisk=<PDISKID>
action=initialize controller=id pdisk=<PDISKID>
action=offline controller=id pdisk=<PDISKID>
action=online controller=id pdisk=<PDISKID>
action=assignglobalhotspare controller=id pdisk=<PDISKID> assign=<yes | no>
action=rebuild controller=id pdisk=<PDISKID>
action=cancelrebuild controller=id pdisk=<PDISKID>
action=cancelreplacemember controller=id pdisk=<PDISKID>
action=clear controller=id pdisk=<PDISKID>
action=cancelclear controller=id pdisk=<PDISKID>
action=enabledevicewritecache controller=id pdisk=<PDISKID>
action=disabledevicewritecache controller=id pdisk=<PDISKID>
action=exportreliabilitylog controller=id pdisk=<PDISKID>
action=convertraidtononraid controller=id pdisk=<PDISKID>
action=convertnonraidtoraid controller=id pdisk=<PDISKID>
Omconfig Blink Physical Disk
Description
Blinks the light (light emitting diode or LED display) on one
or more physical disks attached to a controller.
Syntax
omconfig storage pdisk action=blink
controller=id pdisk=<PDISKID>, where id is
the controller ID. The <PDISKID> variable specifies the
physical disk.
NOTE: To obtain these values, type omreport storage
controller to display the controller IDs and then type
omreport storage pdisk controller=ID to display the
IDs for the physical disks attached to the controller.
Example to Blink physical disk 0 on connector 0 of controller 1. On a
SAS controller, the physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA controllers
omconfig storage pdisk action=blink
controller=1 pdisk=0:0
Example for SAS controllers
omconfig storage pdisk action=blink
controller=1 pdisk=0:2:0
138