Reference Guide

name=value pair Description
warning: Perform a shutdown when a temperature warning event is detected.
A warning event occurs when any temperature probe inside a chassis reads
a temperature (in degree Celsius) that exceeds the maximum temperature
warning threshold value.
failure: Perform a shutdown when a temperature failure event is detected. A
failure event occurs when any temperature probe inside a chassis reads a
temperature (in degree Celsius) that exceeds the maximum temperature
failure threshold value.
Example Thermal Shutdown Commands
To trigger a thermal shutdown when a temperature probe detects a failure event, type:
omconfig system thrmshutdown severity=failure
or
omconfig servermodule thrmshutdown severity=failure
To disable thermal shutdown so that an administrator has to initiate an omconfig system shutdown, type:
omconfig system thrmshutdown severity=disabled
or
omconfig servermodule thrmshutdown severity=disabled
111