Read me

omconfig system webserver action=stop
2. Locate the "keystore.db.bak" file. The default path is
"C:\program files\dell\SysMgt\apache-tomcat\conf".
3. Copy "keystore.db.bak" to "keystore.db".
4. Type:
omconfig system webserver action=start
Issue 14: A temperature drop below a minimum failure threshold does not cause a system reset even if this
alert action is set.
Issue 15: Clicking the "Back" and "Refresh" buttons on the browser may not display the correct page with
respect to the Server Administrator component tree, tabs, tab menus, or help, as Server Administrator has
been designed with limited functionality to reduce overhead.
Full feature capabilities of the Web browser such as "Back", "Refresh", and "Open in New Window" may
not be supported.
Issue 16: Selecting the boot sequence under the BIOS "Setup" tab does not re-enable boot devices that
have been disabled in the System Setup Program, earlier.
Issue 17: The links on the Server Administrator home page may not work after repeated random clicking.
To resolve this issue, refresh the browser by pressing <F5> or click the browser "Refresh" button.
Issue 18: All unsecured HTTP requests to Server Administrator receive an invalid response. Server
Administrator runs only one instance of the Web server, which is secure. Make all connections through
https://<ip address> : <port number>. Any "http://<ip address>: <port number>" request for connection
with the server receives an invalid response.
Issue 19: If the browser used with Server Administrator does not display a page or perform an action, make
sure that the browser is in online mode. To go online, perform the following:
In Internet Explorer, on the menu bar, click "File" and clear the "Work Offline" option. When "Work
Offline" is selected, a check mark is displayed to the left of the option on the "File" menu.
Issue 20: If Internet Explorer prompts you to "Work Offline", "Connect", or "Try Again", always select
"Connect" or "Try Again". Do not select "Work Offline".
Issue 21: While setting dates in the "Asset Information" section of the Server Administrator home page,
the current time is appended to the date.
While setting dates with the CLI, the appended time is noon.
Issue 22: On some systems, temperature probe values and settings are only supported for whole degrees,
not tenths of a degree. On those systems, setting a fractional value for the minimum warning temperature
threshold results in the set value being rounded off to the next whole number value.