Reference Guide
omconfig storage 命令
205
action=createvdisk controller=id raid=<c| r0| r1| r1c|
r5|r6| r10| r50|r60> size=<number | b | m |g |max |
min> pdisk=<PDISKID> [stripesize=< 2kb| 4kb| 8kb|
16kb| 32kb| 64kb| 128kb | 256kb | 512kb | 1mb >]
[cachepolicy=<d | c>] [readpolicy=<ra| nra| ara| rc|
nrc>] [writepolicy=<wb | wt | wc | nwc | fwb>]
[diskcachepolicy=<disabled | enabled>] [name=
<string>] [spanlength=<n>] | [secureflag=yes]
注:
对于固件版本为 6.1 和更高版本的 SAS 控制器上的
RAID 10, spanlength 是可选参数 (默认值 =2)。
action=setrebuildrate controller=id rate=<0 to 100>
action=setchangecontrollerproperties controller=<id>
[bgirate=<rate>][reconstructrate=
<rate>][checkconsistencyrate=<rate>][rebuildrate=
<rate>][clearredundantpath=
clear][abortcheckconsistencyonerror=
<enabled/disabled>][loadbalance=
<auto/disabled>][allowrevertibilehotspareandreplacemem
ber=enabled/disabled]
[autoreplacememberonpredictivefailure=
<enabled/disabled>][persistenthotspare=
enabled/disabled]rate=<0 to 100>
action=discardpreservedcache controller=id force=
<enabled/disabled>
action=createsecuritykey controller=id keyid=<keyid>
passphrase=<passphrase string> [escrow=yes] [filepath=
<Absolute path to the escrow file>]
注:
如果设置 escrow=yes,请指定 escrow 文件路径。
action=changesecuritykey controller=id keyid=<keyid>
passphrase=<passphrase string> oldpassphrase=
<oldpassphrase string> [escrow=yes] [filepath=
<Absolute path to the escrow file>]
注:
如果设置 escrow=yes,请指定 escrow 文件路径。
action=deletesecuritykey controller=id
action=setbgirate controller=id
rate=<0 to 100>
表 8-4. omconfig 控制器命令 (续)
所需命令级别(
1
、
2
、
3
)
可选 “名称 = 值”对