Read me
Table Of Contents
Solution: Use a supported browser other than Internet Explorer 7.x, 8.x or use the Storage Management
command line interface (CLI) to create the virtual disk.
See the Server Administrator readme for information on supported browsers. See the Storage
Management online help or the "Server Administrator Command Line Interface User's Guide" for
information on using the Storage Management CLI.
Issue 20: DF152362: Storage Management may not display controllers installed with the Service and
Diagnostics utility.
Description: Storage Management may not recognize devices that are installed after Storage Management
is already running.
Solution: If Storage Management does not recognize a newly-added device and this problem has not been
corrected with a Global Rescan, then reboot the system.
Issue 21: DF120475: Storage Management SNMP traps are not filtered by Server Administrator.
Description: Server Administrator allows you to filter SNMP traps that you do not want to receive. To
implement SNMP trap filtering, select the "System" tree-> "Alert Management" tab-> "SNMP Traps" subtab.
The "SNMP Traps" subtab has options for enabling and disabling SNMP traps based on severity or the
component that generates the trap. Even when the SNMP traps are disabled, Storage Management
generates SNMP traps.
Solution: SNMP trap filtering will be provided in a future release of Storage Management.
Issue 22: When issuing certain "omconfig storage" CLI commands with "Power User" privileges, the "Error!
User has insufficient privileges to run command: omconfig" message may be displayed. You must be logged
on as an Administrator to perform these actions.
Issue 23: Invalid "Format and Check Consistency" options are displayed for regenerating a virtual disk.
When a physical disk in a virtual disk is rebuilding, the virtual disk changes to a "Regenerating" state. The
Format and Check Consistency operations should not be performed on a virtual disk that is in a
Regenerating" state. However, the task drop-down menu for a "Regenerating" RAID 1-concatenated virtual
disk may display the "Format and Check Consistency" options.
Issue 24: If a physical disk in a RAID 1-concatenated virtual disk fails, the virtual disk is in a "Degraded" state.
Rebooting the system may cause the virtual disk to change to a "Failed" state, but the virtual disk is still
fully-operational and can be restored to "OK" status once a functional physical disk is added back to the
RAID-1 set.
Issue 25: Using the Storage Management Service "Advanced Create VDisk Wizard" may occasionally result
in a vertical scrollbar of less than normal width. If this occurs, resizing the Server Administrator window
causes the vertical scrollbar to be redrawn correctly.
Issue 26: Using the GUI, if a virtual disk is renamed to a name containing multiple blank and consecutive
spaces, the name is truncated to a single space after "Apply" is clicked.