Read me
Table Of Contents
Management page until the session time out occurs, or DSM SA connection service is restarted, or the
operating system is rebooted.
Issue 25: If you change the operating system Time Zone to a new timezone, Server Administrator session
management does not display the time in the new time zone specified. Restart Server Administrator to
display the accurate time for the time zone in the Session Management page.
Issue 26: DF78425: The Server Administrator Auto Recovery feature may execute the configured action
before the time interval when the system is under heavy stress.
The Auto Recovery feature can be set to execute an action (For example, reboot system) to recover a hung
system. Since the Auto Recovery timer is now an application-level timer instead of a kernel-level timer,
heavy resource stress on the system may result in an inaccurate measurement of a short keep alive interval
(less than 120 seconds), and the configured action may be triggered.
The issue is more prevalent in systems that have only one CPU with hyper-threading unsupported/disabled
or systems that are subjected to persistent stressful conditions such as, resource depletion and CPU
running at 100% usage with significantly more threads than normal usage.
The Auto Recovery feature is not enabled by default. If the Auto Recovery feature has been enabled,
increase the System Reset Timer value to at least 120 seconds.
Issue 27: Using the Internet Explorer browser, if you install Server Administrator on a system that includes
an underscore in its hostname, you must use the IP address of the target system in the browser URL to
launch Server Administrator, as Hostnames with underscores are not supported. For example, (assuming
Server Administrator is listening on port 1311):
https://192.168.2.3:1311.
For more information, see the following article on the: Microsoft website -
http://support.microsoft.com/kb/312461
Issue 28: DF 152755: The Server Administrator GUI does not respond when the alerts log has many events.
If the Alert Log contains several entries and if you try to navigate to another page, the Server Administrator
GUI may take about 30 seconds to display the content.
Issue 29: DF 172125: Power monitoring probes are shown on certain systems that do not support power
monitoring.
On certain systems that do not support power monitoring, Server Administrator reports the two platform
event filters related to power monitoring as "System Power Probe Warning" and "System Power Probe
Failure". These two filters are not supported on these systems. That is, you can view and configure these
filters, but no action is taken.
Issue 30: DF185770: Primary User Telephone Number does not accept symbols.
On Server Administrator, Under Asset Information->System Information->Primary User Telephone Number
configuration allows only alphanumeric characters.