omconfig system webserver action=start
Issue 15: A temperature drop below a minimum failure threshold does not cause a system reset even if this
alert action is set.
Issue 16: Clicking the "Back" and "Refresh" buttons on the browser may not display the correct page with
respect to the Server Administrator component tree, tabs, tab menus, or help, as Server Administrator has
been designed with limited functionality to reduce overhead.
Full feature capabilities of the Web browser such as "Back", "Refresh", and "Open in New Window" may
not be supported.
Issue 17: Selecting the boot sequence under the BIOS "Setup" tab does not re-enable boot devices that
have been disabled in the System Setup Program, earlier.
Issue 18: The links on the Server Administrator home page may not work after repeated random clicking.
To resolve this issue, refresh the browser by pressing <F5> or click the browser "Refresh" button.
Issue 19: All unsecured HTTP requests to Server Administrator receive an invalid response. Server
Administrator runs only one instance of the Web server, which is secure. Make all connections through
https://<ip address> : <port number>. Any "http://<ip address>: <port number>" request for connection
with the server receives an invalid response.
Issue 20: If the browser used with Server Administrator does not display a page or perform an action, make
sure that the browser is in online mode. To go online, perform the following:
• In Internet Explorer, on the menu bar, click "File" and clear the "Work Offline" option. When "Work
Offline" is selected, a check mark is displayed to the left of the option on the "File" menu.
Issue 21: If Internet Explorer prompts you to "Work Offline", "Connect", or "Try Again", always select
"Connect" or "Try Again". Do not select "Work Offline".
Issue 22: While setting dates in the "Asset Information" section of the Server Administrator home page,
the current time is appended to the date.
While setting dates with the CLI, the appended time is noon.
Issue 23: On some systems, temperature probe values and settings are only supported for whole degrees,
not tenths of a degree. On these systems, setting a fractional value for the minimum warning temperature
threshold results in the set value being rounded down to the next whole number value.
This behavior may cause the minimum warning threshold to have the same value as the minimum failure
threshold.
Issue 24: If you close the browser using the "Close" button on the browser or log off from the operating
system, the Server Administrator session is not terminated. This session is listed in the Session