Dell OpenManage Server Administrator Version 7.
This document contains updated information for the "Dell OpenManage Server Administrator User's Guide" and any other technical documentation included with Server Administrator. NOTE: Dell OpenManage System Management software, including the Dell OpenManage Server Administrator (Server Administrator), is available only on the "Dell Systems Management Tools and Documentation" DVD.
• • Qlogic P3+ Dual port 10Gb SFP+/DA • Brocade 10Gb CNA (BR1741M-k (New) • Emulex Single Port FC16 HBA • Emulex Dual Port FC16 HBA • Qlogic QLE2460 Single port FC4 Adapter • Qlogic QLE2462 Dual port FC4 Adapter • Brocade BR815- Single Port FC8 Adapter • Brocade BR825- Dual Port FC8 Adapter • Qlogic QLE2562 Dual Port FC8 Adapter • Emulex LPe-12002 Dual Port FC8 Adapter • Qlogic QME2572 Dual Port FC8 Mezz • Emulex Lpe-1205-M Dual Port FC8 Mezz • Qlogic QLE2560 Single Port FC8 Adapter • Emulex LPe-12000 Sing
• • One of the supported systems management protocol standards. For more information, see "Supported Systems Management Protocol Standards". The Server Administrator Remote Access Controller service requires remote access controller (RAC) to be installed on the managed system. See the relevant Dell Remote Access Controller User’s Guide for complete software and hardware requirements.
• • • • • • To allow Single Sign-on for Server Administrator, perform the following steps: 1. In Internet Explorer, navigate to "Tools". 2. Click "Internet Options". 3. Click the "Security" tab. 4. Select "Trusted sites". 5. Click the "Custom Level" button. 6. Under "User Authentication", select the "Automatic Logon with current username and password" radio button. Click ‘OK’ to exit the "Custom Level" window. 7. Now select the "Advanced" tab, and under "HTTP 1.1 settings", make sure "Use HTTP 1.
To improve security, Microsoft provides the capability to encrypt files using EFS. Note that OMSA will not function if its dependent files are encrypted. • Server Administrator GUI and CLI Response Time On Dell PowerEdge x9xx and later systems, the response time for some parts of the Server Administrator GUI and CLI has increased to several seconds as Server Administrator no longer caches some of the DRAC/iDRAC data. The data must be retrieved from the DRAC/iDRAC when you request for it.
Redundancy Lost - The sensors display this status whenever any system fan fails or is removed from the chassis. • • • • If a system with memory redundancy enabled enters a "redundancy lost" state, it may not be clear which memory module caused it. If you cannot determine which DIMM to replace, see the "switch to spare memory detected" log entry in the ESM system log to find the memory module that failed.
• • • • • • • • Issue 5 DF421616 E-Clarity: Page Expired error occurs when the Go Back button is clicked - Inband failure page Issue 6 DF421990 E-clarity: |Om6.
Issues for Server Administrator Web Server running on all Linux Operating Systems * Issue 1: DF275424, DF332775: Domain users unable to login to Windows MN from Linux Web Server. Negotiate authentication is not supported while managing a Windows-based managed node from a Linuxbased Server Administrator Web server, remotely. If you run the Server Administrator Web server on a Linux based operating system and try to manage a remote Windows managed system as domain user, a "login failed" message appears.
Issue 7: While entering the Server Administrator command line "omreport system version -outc ", ensure that you specify an absolute path name for the output file, for example, "c:\out.txt" else, the output file is empty. Issue 8: Entering the "omreport system esmlog/alertlog/cmdlog -fmt tbl" command on the CLI can result in XML parsing errors if the size of the log is very large. Use the GUI or the "omreport system esmlog/alertlog/cmdlog" CLI command to view the contents of the log.
4. Type: omconfig system webserver action=start Issue 15: A temperature drop below a minimum failure threshold does not cause a system reset even if this alert action is set. Issue 16: Clicking the "Back" and "Refresh" buttons on the browser may not display the correct page with respect to the Server Administrator component tree, tabs, tab menus, or help, as Server Administrator has been designed with limited functionality to reduce overhead.
Management page until the session time out occurs, or DSM SA connection service is restarted, or the operating system is rebooted. Issue 25: If you change the operating system Time Zone to a new timezone, Server Administrator session management does not display the time in the new time zone specified. Restart Server Administrator to display the accurate time for the time zone in the Session Management page.
Issue 31: The selection of default option for front panel LCD in Server Administrator displays the Model Name where as the default is Service Tag on the physical LCD. Issue 32: In case Server Administrator does not respond or is locked to your selections on the component tree, perform the following steps: 1. Click “Preferences”. The Preferences page appears. 2. Click “Server Administrator”. The items on the front page may respond to your click.
Workaround: To enable editing of the Server Administrator BIOS attributes, launch Lifecycle Controller while booting. Issue 38: DF552204: On Mozilla Firefox browsers (versions 10, 11 and 12), Server Administrator fails to launch if IPv6 address used. This is a known issue. For more information, see https://bugzilla.mozilla.org/show_bug.cgi?id=633001.
Issue 2: When running Server Administrator, crypt32.dll errors may be written to the operating system Application Event log. This issue occurs due to the "Update Root Certificates" component, which is installed by default as part of Windows Server 2003 installation. For more information on this component and reasons for errors, see the following articles on the Microsoft website: • • http://www.microsoft.com/technet/prodtechnol/windowsserver2003/technologies/security/ws03 mngd/04_s3cer.
interactive applications comprise applications with a Graphical User Interface (GUI) or that prompt users for input in some way such as the "pause" command in a batch file. When Server Administrator is installed on Microsoft Windows Server 2008, the DSM Server Administrator Data Manager Service is installed as a non-interactive service, which means that it is configured for not interacting with the desktop directly.
Issues for Server Administrator running on Red Hat Enterprise Linux Operating Systems Issue 1: When starting Server Administrator from the Red Hat Enterprise Linux console, kernel log messages may appear. To avoid these messages, perform the following steps: 1. Edit the "/etc/sysconfig/syslog" file and modify KLOGD_OPTIONS to KLOGD_OPTIONS="-c 4". 2. Restart "syslog" by executing "/etc/init.d/syslog restart".
"omconfig rac generatecert" The following racadm commands use FTP protocol to communicate with the RAC: "racadm sslcertupload" "racadm sslcsrgen" "racadm fwupdate" Issue 5: If the RAC configuration is reset to factory defaults using the "racadm racresetcfg" command, the RAC configuration tab in Server Administrator does not reflect the reset configuration settings until the system reboots.
Issue 10: Depending on your network and proxy configurations and whether you are using Mozilla browser, you may need to enter the exact IP address of the RAC controller you are trying to access in the "No Proxy for" field of your browser. Perform the following steps: 1. 2. 3. 4. 5. 6. 7. Open your Mozilla browser. Click "Edit". Click "Preferences". Click "Advanced" in the left sidebar. Click "Proxies" in the left sidebar. Enter the RAC IP address in the "No Proxy for:" field.
Internet Explorer 8 has a new security feature called "Loopback security check" which prevents NTLMbased authentication from the local machine. This feature blocks users from performing any set operation in Server Administrator if they are logged in using single sign-on (SSO), (clicking the Server Administrator desktop icon) on Internet Explorer 8. Issue 17: DF380725: On IE or Firefox Web browsers, you cannot attach files to an e-mail if the filename contains non-ASCII letters.
Issue 23: DF532055: From Windows Server 2008 R2 SP1, when an administrator manages Red Hat Enterprise Linux 6.1 (64-bit) or 5.7 (32 and 64-bit) operating systems, Server Administrator reports connection error intermittently. Workaround: Perform the following settings and manage the remote system from webserver. 1. Configure TCP Chimney offload to disable state by running following command: netsh int tcp set global chimney=disabled 2.
Solution: Improvements are being investigated for the OM7.1 timeframe in Q1 of 2012. Until then the number of direct attached drives must be reduced to below 200 if the timeout is encountered. Please allow sufficient time for the VD to be created. Issue 5: Physical disk properties such as Manufacture day, Manufacture week, and Manufacture year are available for SAS drives only. Issue 6: Dell OpenManage Server Administrator Storage Management 7.
successful but the operating system may not be aware of the new virtual disk." However, the virtual disk is available for all operations on rebooting the system. Issue 13: Patrol Read is not supported on SSD media. The Patrol Read feature fails for any controller that has SSD media on a virtual disk. Issue 14: Hot plug of enclosures takes time to enumerate the enclosure and its components.
Solution: Use a supported browser other than Internet Explorer 7.x, 8.x or use the Storage Management command line interface (CLI) to create the virtual disk. See the Server Administrator readme for information on supported browsers. See the Storage Management online help or the "Server Administrator Command Line Interface User's Guide" for information on using the Storage Management CLI. Issue 20: DF152362: Storage Management may not display controllers installed with the Service and Diagnostics utility.
Issue 27: When the "Open in a New Window" option is selected in the Storage Management Service Advanced Create VDisk Wizard, the current page is opened in a new window, rather than launching the selected option. Issue 28: If a physical disk in a RAID 1-concatenated virtual disk fails, the virtual disk is in a "Degraded" state. The Check Consistency operation should not be performed on a virtual disk while it is in a degraded state.
SAS 6/iR Adapter 00.25.47.00/06.22.03.00 SAS 6/int. Modular 00.25.47.00/ 06.22.03.00 PERC H800 Adapter 12.10.2-0004 PERC H700 Integrated 12.10.2-0004 PERC H700 Adapter 12.10.2-0004 PERC H700 Modular 12.10.2-0004 PERC H200 Adapter 07.03.05.00 PERC H200 Integrated 07.03.05.00 PERC H200 Modular 07.03.05.00 PERC H200 Embedded 07.03.05.00 6Gbps SAS HBA 07.03.05.00 PERC H310 Adapter 20.10.1-0084 PERC H310 Mini Monolithic 20.10.1-0084 PERC H310 Mini Blades 20.10.
Windows Drivers for PERC Controllers Windows Drivers for PERC 4e/DC, PERC 5/E, PERC 5/i Integrated, PERC 5/i Adapter, SAS 5/iR Integrated, SAS 5/iR Adapter, SAS 5/i Integrated, SAS 5/E Adapter, PERC 6/E Adapter, PERC 6/i Integrated, PERC 6/i Adapter, SAS 6/iR Integrated, SAS 6/iR Adapter, SAS 6/int.
SAS 6/iR Modular 1.28.03.01 1.28.03.01 1.28.03.01 LSI 1020 on a PowerEdge 1600SC Not Applicable Not Applicable Not Applicable LSI 1030 on a PowerEdge 1750 Not Applicable Not Applicable Not Applicable PERC H800 Adapter 4.31.1.32 4.31.1.64 4.31.1.64 PERC H700 Integrated 4.31.1.32 4.31.1.64 4.31.1.64 PERC H700 Adapter 4.31.1.32 4.31.1.64 4.31.1.64 PERC H700 Modular 4.31.1.32 4.31.1.64 4.31.1.64 PERC H200 Adapter 2.0.12.10 2.0.12.10 2.0.12.10 PERC H200 Integrated 2.0.12.10 2.0.
PERC H710 Mini Monolithic 5.1.90.32 5.1.90.64 5.1.90.64 PERC H710P Adapter 5.1.90.32 5.1.90.64 5.1.90.64 PERC H710P Mini Blades 5.1.90.32 5.1.90.64 5.1.90.64 PERC H710P Mini Monolithic 5.1.90.32 5.1.90.64 5.1.90.64 PERC H810 Adapter 5.1.90.32 5.1.90.64 5.1.90.64 PERC S100 2.0.0-0162 2.0.0-0162 2.0.0-0162 PERC S300 2.0.0-0162 2.0.0-0162 2.0.0-0162 PERC S110 3.0.0.0134 3.0.0.0134 3.0.0.
SAS 5/E Adapter Native 4.00.38.02-3 Native Native PERC 6/E Adapter Native Native Native Native PERC 6/i Integrated Native Native Native Native PERC 6/i Adapter Native Native Native Native SAS 6/iR Integrated Native 4.00.38.02-3 Native Native SAS 6/iR Adapter Native 4.00.38.02-3 Native Native SAS 6/int. Modular Native 4.00.38.
PERC H310 Mini Blades Native 00.00.05.38 Native Native PERC H710 Adapter Native 00.00.05.38 Native Native PERC H710 Mini Blades Native 00.00.05.38 Native Native PERC H710 Mini Monolithic Native 00.00.05.38 Native Native PERC H710P Adapter Native 00.00.05.38 Native Native PERC H710P Blades Native 00.00.05.38 Native Native PERC H710P Mini Monolithic Native 00.00.05.38 Native Native PERC H810 Adapter Native 00.00.05.
Global Support For information on technical support, visit www.dell.com/contactus. For information on documentation support, visit support.dell.com/manuals. On the Manuals page, click Software ->Systems Management. Click on the specific product on the right -side to access the documents. Information in this document is subject to change without notice. © 2012 Dell Inc. All rights reserved. Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc.