Reference Guide

62 omreport: Viewing System Status Using the Instrumentation Service
Failure Threshold
Amperage: Location and Reading
Power Tracking Statistics
Energy Consumption
Measurement Start Time
Measurement Finish Time
•Reading
System Peak Power
System Peak Amperage
NOTE: The omreport chassis pwrmonitoring or omreport mainsystem
pwrmonitoring command is applicable from PowerEdge yx0x system onwards that
support PMBus and that have hot-swappable power supplies and not systems that
have a fixed, non-redundant power supply installed.
NOTE: Power monitoring requires license to report the details. If the appropriate
license is not installed or has expired, the system does not display the power
consumption details of the system. For more information, see The Dell Licensing
Management Guide at support.dell.com/manuals.
NOTE: To maintain consistency across the commands, the output format of this
command has changed. Change the user scripts as applicable.
Table 3-5. omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring
name=value pair Description
config=stats Reports power statistics in Watts.