User's Manual
286 Troubleshooting
• Rebuild for PERC 4/SC, 4/DC, 4e/DC, 4/Di, PERC 5/E and PERC 5/i
controllers
You can avoid removing the wrong physical disk by blinking the LED display
on the physical disk that you intend to remove. For information on blinking
the LED display, see Blink and Unblink (Physical Disk).
Resolving Microsoft Windows Upgrade Problems
If you upgrade the Microsoft Windows operating system on a server, you may
find that Storage Management no longer functions after the upgrade. The
installation process installs files and makes registry entries on the server that
are specific to the operating system. For this reason, changing the operating
system can disable Storage Management.
To avoid this problem, you should uninstall Storage Management before
upgrading. If you have already upgraded without uninstalling Storage
Management, however, you should uninstall Storage Management after the
upgrade.
After you have uninstalled Storage Management and completed the upgrade,
reinstall Storage Management using the Storage Management install media.
You can download Storage Management from support.dell.com.
Virtual Disk Troubleshooting
The following sections describe troubleshooting procedures for virtual disks.
• Replacing a Failed Disk that is Part of a Redundant Virtual Disk
• Replacing a Failed Physical Disk in a RAID 1 on a CERC SATA1.5/2s
•A Rebuild Does Not Work
• A Rebuild Completes with Errors
• Cannot Create a Virtual Disk
• Virtual Disk Errors on Linux
• Problems Associated With Using the Same Physical Disks for Both
Redundant and Non-Redundant Virtual Disks
A Rebuild Does Not Work
A rebuild does not work in the following situations: