User's Manual

Virtual Disks 259
3
Select the
Virtual Disks
object.
4
Select
Rename
from the
Available Tasks
drop-down menu.
5
Click
Execute.
Virtual Disk Task: Change Policy
Does my controller support this feature? See Supported Features.
Use the Change Policy task to change a virtual disk’s read, write, or cache
policy. For more information, see RAID Controller Read, Write, Cache, and
Disk Cache Policy.
To change a virtual disk’s read, write, or disk cache policy:
1
Select the new policy from the
Read Policy
,
Write Policy
, and
Disk
Cache Policy
drop-down menus.
2
Click
Apply Changes
. To exit without changing the virtual disk policy,
click
Go Back To Virtual Disk Page
.
To locate this task in Storage Management:
1
Expand the
Storage
tree object to display the controller objects.
2
Expand a controller object.
3
Select the
Virtual Disks
object.
4
Select
Change Policy
from the
Available Tasks
drop-down menu.
5
Click
Execute.
Split Mirror
Does my controller support this feature? See Supported Features.
Use the Split Mirror task to separate mirrored data originally configured as a
RAID 1, RAID 1-concatenated, or RAID 10 virtual disk. Splitting a RAID 1 or
RAID 1-concatenated mirror creates two concatenated non-redundant virtual
disks. Splitting a RAID 10 mirror creates two RAID 0 (striped) non-
redundant virtual disks. Data is not lost during this operation.
NOTE: The Split Mirror task is not supported on the CERC SATA1.5/2s controller.