User's Manual

Virtual Disks 223
Exceptions for Reconfiguring a Concatenated Virtual Disk on CERC SATA1.5/6ch
and CERC SATA1.5/2s Controllers
You can create a concatenated virtual disk by performing a Split Mirror or an
Unmirror on a RAID 1-concatenated virtual disk. After you have done so,
however, the resulting concatenated virtual disks cannot be subjected to any
further modification. You cannot reconfigure or add disks to the resulting
concatenated virtual disks.
Maintain Integrity of Redundant Virtual Disks
Does my controller support this feature? See Supported Features.
The virtual disk Check Consistency task verifies the accuracy of the
redundant (parity) information. This task only applies to redundant virtual
disks. When necessary, the Check Consistency task rebuilds the redundant
data.
To verify a virtual disk’s redundant information:
1
Locate the controller on which the virtual disk resides in the tree view.
Expand the controller object until the
Virtual Disks
object is displayed.
2
Select the
Check Consistency
task from the virtual disk’s drop-down
menu and click
Execute
.
PERC S100, S110,
and S300
RAID 0RAID 0With or without
additional disks
RAID 1RAID 1Without additional
disks
RAID 5RAID 5With or without
additional disks
RAID 10 RAID 10 Without additional
disks
Table 12-1. Virtual Disk Reconfiguration and Capacity Expansion
(continued)
Controller Starting RAID Level Target RAID Level Comments