User's Manual

184 RAID Controller Batteries
Predicted Capacity
Status
This property displays the charge capacity of the battery.
Possible values are:
ReadyThe battery can be charged to full capacity.
Failed—The battery cannot be charged and needs to be
replaced.
Unknown—The battery is completing a Learn cycle. The
charge capacity of the battery cannot be determined until
the Learn cycle is complete.
Learn State This property displays the current status of the battery
learn cycle. Possible values are:
Active—The Learn cycle is currently in progress.
FailedThe Learn cycle initiated but then terminated
without completing successfully.
Timed outThe Learn cycle is timed out.
RequestedThe Learn State displays Requested when
either the controller firmware or a user attempts to initiate
a Learn cycle while the battery is charging. The battery
must be fully charged before the Learn cycle begins. The
Learn State displays Requested until the battery is fully
charged. When the battery is fully charged, the Learn cycle
begins.
Idle—The Learn cycle is currently not active.
Due—The Learn cycle is due.
Learn Mode Auto—Storage Management performs an automatic learn
cycle based on the time you set.
Warn—The Learn cycle is past the default 90 days.
NOTE: Warn is available only on SAS controllers with
firmware version 6.1 and later.
When the battery is in Warn mode, the status of the
controller is displayed as degraded.
Next Learn Time This property displays the number of days and hours left
before the controller firmware initiates the next Learn
cycle.
Property Definition