SNMP Reference Guide
712 Traps
Fan Enclosure Traps
Some systems are equipped with a protective enclosure for fans. Fan
enclosure traps monitor enclosures for whether foreign objects are present
and for how long a fan enclosure is absent from a chassis.
1404 Memory device status: <Status>
Memory device location:
<Location in chassis>
Possible memory module event
cause: <list of causes>
Error A memory device correction
rate exceeded an acceptable
value, a memory spare bank
was activated, or a
Uncorrectable Memory
Event occurred. The system
continues to function
normally (except for a
Uncorrectable Memory
Event). Clear the memory
error on Uncorrectable
Memory Event. Replace the
memory module identified in
the message during the
system’s next scheduled
maintenance. The memory
device status and location are
provided.
Table 27-11. Fan Enclosure Traps
TrapID Description Severity Cause
Fan Enclosure Insertion
1452 Fan enclosure inserted into
system
Sensor location: <Location in
chassis>
Chassis location: <Name of
chassis>
Information A fan enclosure has been
inserted into the specified
system. The sensor
location and chassis
location are provided.
Table 27-10. Memory Device Messages
(continued)
TrapID Description Severity Cause
book.book Page 712 Tuesday, February 28, 2012 2:19 PM