Reference Guide

Storage Management Message Reference 83
2077 Virtual disk
format failed.
Critical /
Failure / Error
Cause: A physical disk
included in the virtual
disk failed.
Action: Replace the
failed physical disk. You
can identify which
physical disk has failed
by locating the disk that
has a red X for its
status. Rebuild the
physical disk. When
finished, restart the
virtual disk format
operation.
Clear Alert
Number:
None
Related
Alert
Number:
None
LRA
Number:
2081
1204
2079 Virtual disk
initialization
failed.
Critical /
Failure / Error
Cause: A physical disk
included in the virtual
disk has failed or a user
has cancelled the
initialization.
Action: If a physical
disk has failed, then
replace the physical
disk.
Clear Alert
Number:
None
Related
Alert
Number:
None
LRA
Number:
2081
1204
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers