Reference Guide

Storage Management Message Reference 75
2056 Virtual disk
failed
Critical /
Failure / Error
Cause: One or more
physical disks included in
the virtual disk have
failed. If the virtual disk
is non-redundant (does
not use mirrored or parity
data), then the failure of
a single physical disk can
cause the virtual disk to
fail. If the virtual disk is
redundant, then more
physical disks have failed
than can be rebuilt using
mirrored or parity
information.
Action:
Create a new
virtual disk and restore
from a backup.
Clear Alert:
None
Related
Alert
Number:
2048, 2049,
2050, 2076,
2079, 2081,
2129, 2346
LRA
Number:
2081
1204
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers