Reference Guide

Server Management Messages 29
Voltage Sensor Messages
The voltage sensors listed in Table 2-4 monitor the number of volts across
critical components. Voltage sensor messages provide status and warning
information for voltage sensors in a particular chassis.
Table 2-4. Voltage Sensor Messages
Event
ID
Description Severity Cause
1150 Voltage sensor has failed
Sensor location: <Location
in chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
If sensor type is not
discrete:
Voltage sensor value (in
Volts): <Reading>
If sensor type is discrete:
Discrete voltage state:
<State>
Error A voltage sensor in
the specified system
failed. The sensor
location, chassis
location, previous
state, and voltage
sensor value
information is
provided.
1151 Voltage sensor value unknown
Sensor location: <Location
in chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
If sensor type is not
discrete:
Voltage sensor value
(in Volts): <Reading>
If sensor type is discrete:
Discrete voltage state:
<State>
Information A voltage sensor in
the specified system
could not obtain
a reading. The sensor
location, chassis
location, previous
state, and a nominal
voltage sensor value
are provided.