Reference Guide
260 System Event Log Messages for IPMI Systems
Memory Add
(BANK# DIMM#) presence was
asserted
Information This event is generated when
memory is added to the system.
Memory Removed
(BANK# DIMM#) presence was
asserted
Information This event is generated when
memory is removed from the
system.
Memory Cfg Err
configuration error (BANK#
DIMM#) was asserted
Critical This event is generated when
memory configuration is
incorrect for the system.
Mem Redun Gain
redundancy regained
Information This event is generated when
memory redundancy is regained.
Mem ECC Warning
transition to non-critical
from OK
Warning This event is generated when
correctable ECC errors have
increased from a normal rate.
Mem ECC Warning
transition to critical
from less severe
Critical This event is generated when
correctable ECC errors reach a
critical rate.
Mem CRC Err
transition to
non-recoverable
Critical This event is generated
when CRC errors enter a
non-recoverable state.
Mem Fatal SB CRC
uncorrectable ECC was
asserted
Critical This event is generated while
storing CRC errors to memory.
Mem Fatal NB CRC
uncorrectable ECC was
asserted
Critical This event is generated while
removing CRC errors from
memory.
Mem Overtemp
critical over temperature
was asserted
Critical This event is generated when
system memory reaches critical
temperature.
Table 4-12. BIOS Generated System Events
(continued)
Event Message Severity Cause