Reference Guide

256 System Event Log Messages for IPMI Systems
Drive <Drive #>
hot spare was deasserted
Informational This event is generated
when the drive is taken out
of hot spare.
Drive <Drive #>
consistency check in
progress was asserted
Warning Thi s eve nt is ge nerated
when the drive is placed in
consistency check.
Drive <Drive #>
consistency check in
progress was deasserted
Informational This event is generated
when the consistency
check of the drive is
completed.
Drive <Drive #>
in critical array was
asserted
Critical This event is generated
when the drive is placed in
critical array.
Drive <Drive #>
in critical array was
deasserted
Informational This event is generated
when the drive is removed
from critical array.
Drive <Drive #>
in failed array was asserted
Critical This event is generated
when the drive is placed in
the fail array.
Drive <Drive #>
in failed array was
deasserted
Informational This event is generated
when the drive is removed
from the fail array.
Drive <Drive #>
rebuild in progress was
asserted
Informational This event is generated
when the drive is
rebuilding.
Drive <Drive #>
rebuild aborted was asserted
Warning Thi s eve nt is ge nerated
when the drive rebuilding
process is aborted.
Drive <Drive #> is installed. Informational This event is generated
when the drive is installed.
Drive <Drive #> is removed. Critical This event is generated
when the drive is removed.
Table 4-10. Drive Events
(continued)
Event Message Severity Cause