Reference Guide

System Event Log Messages for IPMI Systems 255
Drive Events
The drive event messages monitor the health of the drives in a system.
These events are generated when there is a fault in the drives indicated.
Table 4-9. Hardware Log Sensor Events
Event Message Severity Cause
Log full
detected.
Critical This event is generated when the SEL device
detects that only one entry can be added to
the SEL before it is full.
Log cleared. Information This event is generated when the SEL
is cleared.
Table 4-10. Drive Events
Event Message Severity Cause
Drive <Drive #> asserted
fault state.
Critical This event is generated
when the specified drive in
the array is faulty.
Drive <Drive #> de-asserted
fault state.
Information This event is generated
when the specified drive
recovers from a faulty
condition.
Drive <Drive #>
drive presence was asserted
Informational This event is generated
when the drive is installed.
Drive <Drive #>
predictive failure was
asserted
Warning This event is generated
when the drive is about to
fail.
Drive <Drive #>
predictive failure was
deasserted
Informational This event is generated
when the drive from earlier
predictive failure is
corrected.
Drive <Drive #>
hot spare was asserted
Warning This event is generated
when the drive is placed in
a hot spare.