Reference Guide

252 System Event Log Messages for IPMI Systems
Memory Events
The memory modules can be configured in different ways in
particular systems. These messages monitor the status, warning,
and configuration information about the memory modules in the system.
The OS watchdog timer
powered cycle the
system.
Critical This event is generated when the
BMC watchdog detects that the
system has crashed (timer expired
because no response was received
from Host) and the action is set to
power cycle.
The OS watchdog timer
powered off the
system.
Critical This event is generated when the
BMC watchdog detects that the
system has crashed (timer expired
because no response was received
from Host) and the action is set to
power off.
The OS watchdog timer
expired.
Critical This event is generated when the
BMC watchdog timer expires and no
action is set.
Table 4-8. Memory Events
Event Message Severity Cause
Memory RAID
redundancy
degraded.
Warning This event is generated when there is
a memory failure in a RAID-configured
memory configuration.
Memory RAID
redundancy lost.
Critical This event is generated when redundancy
is lost in a RAID-configured
memory configuration.
Memory RAID
redundancy
regained
Information This event is generated when the
redundancy lost or degraded earlier is
regained in a RAID-configured
memory configuration.
Table 4-7. BMC Watchdog Events
(continued)