Reference Guide
System Event Log Messages for IPMI Systems 249
An over current fault
detected on power supply
<number>.
Critical The specified power supply
detected an over current
condition.
Fan failure detected on
power supply <number>.
Critical The specified power supply fan
has failed.
Communication has been
restored to power supply
<number>.
Information This event is generated when the
power supply has recovered from
an earlier communication
problem.
A power supply wattage
mismatch is detected;
power supply <number> is
rated for <value> watts.
Critical This event is generated when
there is more than one power
supplies in the system and the
power supply wattage do not
match.
Power supply <number>
wattage mismatch
corrected.
Information This event is generated when the
power supply has recovered from
an earlier power supply wattage
mismatch.
Power supply redundancy
is lost.
Critical Power supply redundancy is lost if
only one power supply is
functional.
Power supply redundancy
is degraded.
Warning Power supply redundancy is
degraded if one of the power
supply sources is removed or
failed.
The power supplies are
redundant.
Information This event is generated if the
power supply has been
reconnected or replaced.
Table 4-5. Power Supply Events
(continued)
Event Message Severity Cause