248 System Event Log Messages for IPMI Systems
A predictive failure
detected on power supply
<number>.
Warning This event is generated when the
power supply is about to fail.
The power input for power
supply <number> is lost.
Critical This event is generated when
input power is removed from the
power supply.
The input power for power
supply <number> has been
restored.
Information This event is generated if the
power supply has been
reconnected or replaced.
Power supply <number> is
incorrectly configured.
Critical /
War nin g
This event is generated when an
invalid power supply
configuration is detected.
Power supply <number> is
correctly configured.
Information This event is generated when the
power supply has recovered from
an earlier invalid configuration.
Power supply <number> is
operating normally.
Information This event is generated when the
power supply has recovered from
an earlier failure event.
Cannot communicate with
power supply <number>.
Critical The power supply may operate,
however power supply monitoring
is degraded.
The temperature for power
supply <number> is in a
warning range.
Warning Temperature of specified power
supply entered into non-critical
state.
The temperature for power
supply <number> is
outside of range.
Critical Temperature of specified power
supply entered into critical state.
An under voltage fault
detected on power supply
<number>.
Critical The specified power supply
detected inefficient voltage.
An over voltage fault
detected on power supply
<number>.
Critical The specified power supply
detected an over voltage
condition.
Table 4-5. Power Supply Events
(continued)
Event Message Severity Cause