Reference Guide
System Event Log Messages for IPMI Systems 243
Processor Status Events
The processor status messages monitor the functionality of the processors in a
system. These messages provide processor health and warning information of
a system.
Fan redundancy is
lost.
Critical One or more required fans may have
failed or removed and hence, the
redundancy was lost.
Fan redundancy is
degraded.
Warning One or more fans may have failed or
removed and hence, the redundancy
has been degraded.
Table 4-4. Processor Status Events
Event Message Severity Cause
<Processor Entity> status
processor sensor IERR,
where <Processor Entity>
is the processor that
generated the event. For
example, PROC for a single
processor system and PROC
# for multiprocessor
system.
Critical IERR internal error generated by
the <Processor Entity>.
This event is generated due to
processor internal error.
<Processor Entity> status
processor sensor Thermal
Trip.
Critical The processor generates this
event before it shuts down
because of excessive heat caused
by lack of cooling or heat
synchronization.
<Processor Entity>
status processor sensor
recovered from IERR.
Information This event is generated when a
processor recovers from the
internal error.
<Processor Entity> status
processor sensor disabled.
Warning This event is generated for all
processors that are disabled.
Table 4-3. Fan Sensor Events
(continued)
Event Message Severity Cause