Reference Guide

190 Storage Management Message Reference
2311 The firmware
on the EMMs
is not the same
version.
EMM0 %1
EMM1 %2
Warning /
Non-critical
Cause: The firmware on
the EMM modules
is not the same version.
It is required that both
modules have the same
version of the firmware.
This alert may be
caused if you attempt to
insert an EMM module
that has a different
firmware version than
an existing module. The
%1 and %2 indicate a
substitution variable.
The text for these
substitution variables is
displayed with the alert
in the alert log and can
vary depending on the
situation.
Action: Upgrade to the
same version of the
firmware on both EMM
modules.
Clear Alert:
None
Related
Alert: None
LRA
Number:
2090
853
2312 A power supply
in the
enclosure has
an AC failure.
Warning /
Non-critical
Cause: The power
supply has an AC
failure.
Action: Replace the
power supply.
Clear Alert
Number:
2325
Related
Alert
Number:
2122, 2324.
LRA
Number:
2090
1003
Table 3-4. Storage Management Messages