Reference Guide
166 Storage Management Message Reference
2263 SMART
thermal
shutdown is
disabled.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
101
2264 A device is
missing.
Warning /
Non-critical
Cause: The controller
cannot communicate
with a device. The
device may be removed.
There may also be a bad
or loose cable.
Action: Check if the
device is in and not
removed. If it is in,
check the cables. Also
check the connection to
the controller battery
and the battery health.
A battery with a weak or
depleted charge
may cause this alert.
Clear Alert:
None
Related
Alert: None
LRA
Number:
2050, 2060,
2070, 2080,
2090, 2100
753
803
853
903
953
1003
1053
1103
1153
1203
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers