Reference Guide
152 Storage Management Message Reference
2211 The physical
disk is not
supported.
Warning /
Non-critical
Cause: The physical
disk may not have a
supported version of the
firmware or the disk
may not be supported
by Dell.
Action: If the disk is
supported by Dell,
update the firmware to
a supported version. If
the disk is not
supported by Dell,
replace the disk with
one that is supported.
Clear Alert:
None
Related
Alert: None
LRA
Number:
2070
903
2212 The controller
battery
temperature is
above normal.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
1151
2213 Recharge
count
maximum
exceeded
Warning /
Non-critical
Cause: The battery has
been recharged more
times than the battery
recharge limit allows.
Action: Replace the
battery pack.
Clear Alert:
None
Related
Alert: None
LRA
Number:
2100
1153
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers