Reference Guide

Storage Management Message Reference 135
2170 The controller
battery charge
level is normal.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
1151
2171 The controller
battery
temperature is
above normal.
Warning /
Non-critical
Cause: The battery may
be recharging, the room
temperature may be too
hot, or the fan in the
system may be degraded
or failed.
Action: If this alert was
generated due to a
battery recharge, the
situation is corrected
when the recharge is
complete. You should
also check if the room
temperature is normal
and that the system
components are
functioning properly.
Clear Alert
Number:
2172
Related
Alert: None
LRA
Number:
2100
1153
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers