Reference Guide
134 Storage Management Message Reference
2168 The non-RAID
SCSI driver
version is older
than the
minimum
required level.
See readme.txt
for the
validated
driver version.
Warning /
Non-critical
Cause: The version of
the driver does not
meet the minimum
requirements. Storage
Management may not
be able to display the
storage or perform
storage management
functions until you have
updated the system to
meet the minimum
requirements.
Action: See the Readme
file for the validated
driver version. Update
the system to meet the
minimum requirements
and then reinstall
Storage Management.
Clear Alert:
None
Related
Alert: None
LRA
Number:
2050
103
2169 The controller
battery needs
to be replaced.
Critical /
Failure / Error
Cause: The controller
battery cannot be
recharged. The battery
may be old or it may
have been already
recharged the
maximum number of
times. In addition, the
battery charger may not
be working.
Action: Replace the
battery pack.
Clear Alert:
None
Related
Alert
Number:
2118
LRA
Number:
2101
1154
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers