Reference Guide
Storage Management Message Reference 111
2123 Redundancy
lost
Warning /
Non-critical
Cause: A virtual disk or
an enclosure has lost
data redundancy. In the
case of a virtual disk,
one or more physical
disks included in the
virtual disk have failed.
Due to the failed
physical disk or disks,
the virtual disk is no
longer maintaining
redundant (mirrored or
parity) data. The failure
of an additional
physical disk results in
lost data. In the case of
an enclosure, more than
one enclosure
component has failed.
For example, the
enclosure may have
suffered the loss of all
fans or all power
supplies.
Action: Identify and
replace the failed
components. To identify
the failed component,
select the Storage
object and click the
Health subtab.
Clear Alert
Number:
2124
Related
Alert
Number:
2048, 2049,
2057
LRA
Number:
2080, 2090
1306
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers