Reference Guide

10 Introduction
Memory Prefailure Sensor
— Monitors memory modules by counting the
number of Error Correction Code (ECC) memory corrections.
Fan Enclosure Sensor
— Monitors protective fan enclosures by detecting
their removal from and insertion into the system, and by measuring how
long a fan enclosure is absent from the chassis. This sensor monitors the
chassis and in attached system(s).
AC Power Cord Sensor
— Monitors the presence of AC power for an
AC power cord.
Hardware Log Sensor
— Monitors the size of a hardware log.
Processor Sensor
— Monitors the processor status in the system.
Pluggable Device Sensor
— Monitors the addition, removal,
or configuration errors for some pluggable devices, such as memory cards.
Battery Sensor
— Monitors the status of one or more batteries in
the system.
SD Card Device Sensor
— Monitors instrumented Secure Digital (SD)
card devices in the system.
Sample Event Message Text
The following example shows the format of the event messages logged by
Server Administrator.
EventID: 1000
Source: Server Administrator
Category: Instrumentation Service
Type: Information
Date and Time: Mon Oct 21 10:38:00 2002
Computer: <computer name>
Description:
Server Administrator starting
Data: Bytes in Hex