Reference Guide
150
omconfig storage 命令
action=createvdisk controller=id raid=<c| r0| r1| r1c| r5|r6|
r10| r50|r60> size=<number | b | m |g |max | min> pdisk=
<PDISKID> [stripesize=< 2kb| 4kb| 8kb| 16kb| 32kb| 64kb|
128kb | 256kb | 512kb | 1mb >] [cachepolicy=<d | c>]
[readpolicy=<ra| nra| ara| rc| nrc>] [writepolicy=<wb | wt |
wc | nwc | fwb>] [diskcachepolicy=<disabled | enabled>]
[name=<string>] [spanlength=<n>] | [secureflag=yes]
注:
对于固件版本为 6.1 和更高版本的 SAS 控制器上的
RAID 10, spanlength 是可选参数 (默认值 =2)。
action=setrebuildrate controller=id rate=<0 to 100>
action=setchangecontrollerproperties controller=<id>
[bgirate=<rate>][reconstructrate=
<rate>][checkconsistencyrate=<rate>][rebuildrate=
<rate>][clearredundantpath=
clear][abortcheckconsistencyonerror=
<enabled/disabled>][loadbalance=
<auto/disabled>][allowrevertibilehotspareandreplacemember=
enabled/disabled] [autoreplacememberonpredictivefailure=
<enabled/disabled>][persistenthotspare=
enabled/disabled]rate=<0 to 100>
action=discardpreservedcache controller=id force=
<enabled/disabled>
action=createsecuritykey controller=id keyid=<keyid>
passphrase=<passphrase string> [escrow=yes] [filepath=
<Absolute path to the escrow file>]
注:
如果设置 escrow=yes,请指定 escrow 文件路径。
action=changesecuritykey controller=id keyid=<keyid>
passphrase=<passphrase string> oldpassphrase=
<oldpassphrase string> [escrow=yes] [filepath=<Absolute path
to the escrow file>]
注:
如果设置 escrow=yes,请指定 escrow 文件路径。
action=deletesecuritykey controller=id
action=setbgirate controller=id
rate=<0 to 100 >
action=setreconstructrate controller=id
rate=<0 to 100>
表 8-4. omconfig 控制器命令 (续)
所需命令级别
(1、 2、 3)
可选 “名称 = 值”对