Command Line Interface Guide

omreport: Viewing System Status Using the Instrumentation Service 85
The three properties that display for thermal shutdown are disabled, warning,
or failure. If the CLI displays the following message, the thermal shutdown
feature has been disabled:
Thermal protect shutdown severity: disabled
If the system is configured to shutdown when a temperature probe detects
a warning or failure event, one of the following messages displays:
Thermal protect shutdown severity: warning
Thermal protect shutdown severity: failure
omreport system version or omreport servermodule version
Use the omreport system version or omreport servermodule version
command to list the version numbers of the BIOS, firmware, systems
management software, and operating system installed on the system.
Example Command Output
Ty p e :
omreport system version
or
omreport servermodule version
NOTE: If iDRAC is installed, Server Administrator displays the LCC version. If BMC
is installed, Server Administrator displays the USC version.
The output that is displayed in the CLI window depends on the version of the
BIOS, RAID controllers, and firmware installed on the system. The following
partial command results are unique and may not resemble the results for the
configuration of the system:
Version Report
---------------------
Main System Chassis
---------------------
Name : BIOS
Version : 0.3.5
Name : iDRAC7
Version : 1.00