Command Line Interface Guide

52 omreport: Viewing System Status Using the Instrumentation Service
omreport chassis leds or omreport mainsystem leds
Use the omreport chassis leds or omreport mainsystem leds command to find
out whether clear hard drive fault is supported and what severity level lights
up the LED. Type:
omreport chassis leds index=n
or
omreport mainsystem leds index=n
The index parameter is optional. If you do not specify the index, Server
Administrator displays a summary of LED information for chassis 0. If you
specify the index, Server Administrator displays a summary for a specific
chassis.
The following is an example output:
omreport chassis memory or omreport mainsystem memory
Use omreport chassis memory or omreport mainsystem memory to view
details for each memory module slot in the system. If the system supports
redundant memory, this command also displays the status, state, and type of
memory redundancy implemented on the system. Type:
omreport chassis memory index=n
or
omreport mainsystem index=n
The index parameter is optional. If you do not specify the index, Server
Administrator displays information for all memory modules on the system.
If you specify the index, Server Administrator displays a summary for a
specific memory module.
NOTE: To maintain consistency across the commands, the output format of this
command and the subsequent command levels has changed. So, you may have to
change the user scripts as applicable.
Main System Chassis
Flash chassis identify LED state
Flash chassis identify LED timeout
value
: Off
: 300