Command Line Interface Guide

276 omconfig storage Commands
For global hot spare protection policy, type:
omconfig storage globalinfo action=
setprotectionpolicies type=ghs hscount=<1-16>
warnlevel=<0-3> includeghsinvdstate=<yes | no>
where hscount is the number of hot spares assigned to the virtual disk
and
warnlevel
is the severity level you want to assign to the generated alert,
if this policy is violated. Use
hscount=0 warnlevel=0
to reset the global
hot spare protection policy for the RAID level.
omconfig Connector Commands
The following sections provide the omconfig command syntax required to
execute connector tasks.
omconfig Rescan Connector
Use the following omconfig command to rescan a controller connector. This
command rescans all connectors on the controller and is therefore similar to
performing a controller rescan.
NOTE: This command is not supported on SAS controllers.
Complete Syntax
omconfig storage connector action=rescan
controller=id connector=id
where id is the controller ID and the connector ID as reported by the
omreport command. To obtain these values, type omreport storage controller
to display the controller IDs and then type omreport storage connector
controller=ID to display the IDs for the connectors attached to the
controller.
Table 8-13. omconfig Connector Commands
Required Command Levels (1, 2, 3) Optional name=value pairs
omconfig storage connector
action=rescan controller=id connector=id