Command Line Interface Guide

omconfig storage Commands 269
Example for SCSI, SATA, and ATA Controllers
In this example, temperature probe 3 resides in the enclosure attached to
connector 2 on controller 1. To reset the thresholds for temperature probe 3
to the default values, type:
omconfig storage enclosure action=resettempprobes
controller=1 enclosure=2 index=3
omconfig Set All Temperature Probe Thresholds
Use the following omconfig command syntax to set the minimum and
maximum warning temperature thresholds for all temperature probes in the
enclosure.
NOTE: This command is not supported on SCSI RAID controllers.
Complete Syntax
omconfig storage enclosure action=setalltempprobes
controller=id enclosure=<ENCLOSUREID> minwarn=n
maxwarn=n
where id is the controller ID. The <ENCLOSUREID> variable specifies the
enclosure.
Example Syntax
For example, you may want to specify the minimum and maximum warning
thresholds for all temperature probes to 10 and 40 degree Celsius.
Example for SAS Controllers
In this example, the temperature probes reside in enclosure 3 attached to
connector 2 on controller 1. To set the thresholds for all temperature probes
to 10 and 40
degree Celsius, type:
omconfig storage enclosure action=setalltempprobes
controller=1 enclosure=2:3 minwarn=10 maxwarn=40