Command Line Interface Guide

omconfig storage Commands 211
omconfig Blink Physical Disk
You can blink the light (light emitting diode or LED display) on one or more
physical disks attached to a controller. Use the following omconfig command
syntax to blink one or more physical disks.
Complete Syntax
omconfig storage pdisk action=blink controller=id
pdisk=<PDISKID>
where id is the controller ID. The <PDISK> variable specifies the physical
disk.
To obtain these values, type omreport storage controller to display the
controller IDs and then type omreport storage pdisk controller=ID to
display the IDs for the physical disks attached to the controller.
Example Syntax
In this example, to blink physical disk 0 on connector 0 of controller 1. On a SAS
controller, the physical disk resides in enclosure 2.
action=cancelclear controller=id pdisk=<PDISKID>
action=enabledevicewritecache controller=id pdisk=
<PDISKID>
action=disabledevicewritecache controller=id pdisk=
<PDISKID>
action=exportreliabilitylog controller=id pdisk=
<PDISKID>
action=convertraidtononraid controller=id pdisk=
<PDISKID>
action=convertnonraidtoraid controller=id pdisk=
<PDISKID>
Table 8-2. omconfig Physical Disk Commands
(continued)
Required Command Levels
(1, 2, 3)
Optional name=value pairs