Message:
BIOS setup configured successfully. Change will
take effect after the next reboot.
Command:
omconfig system assetinfo info=depreciation
duration=6
Message:
Asset information set successfully.
NOTE: Due to limitations, some commands do not alter the system settings
eventhough the commands are executed successfully. This is an expected
behavior.
Failure Messages
CLI failure messages provide reasons why some commands do not succeed.
Some common reasons why commands fail include syntax errors and
components that are not present. Many error messages provide syntax
information to execute the command successfully.
If you execute a command for a component or feature not present in the
system configuration, the error message states that the component is not
present.
Command:
omconfig chassis volts index=3 minwarnthresh=
3.3000
Example message:
Error! Number with up to 3 digits after decimal
point expected, read 3.3000
The value given by the command specifies more than
3 digits after the decimal point. A valid minimum
warning threshold value for volts contains up to
3 digits after the decimal point.
Ty p e :
omconfig chassis volts index=3 minwarnthresh=3.300