Command Line Interface Guide

omconfig: Managing Components Using the Instrumentation Service 161
event=batterywarn Sets action or enables or disables alert generation
when a battery device detects that the battery is
pending a failure condition.
event=batteryfail Sets action or enables or disables alert generation
when a battery device detects that the battery has
failed.
event=discretevolt Sets action or enables or disables alert generation
when a discrete voltage probe detects that the voltage
is too low for proper operation.
event=fanfail Sets action or enables or disables alert generation
when a fan probe detects that the fan is running too
slow or not at all.
event=hardwarelogfail Enables or disables alert generation when a hardware
log detects a failure value.
event=intrusion Sets action or enables or disables alert generation
when a chassis is opened.
event=powerwarn Sets action or enables or disables alert generation
when a power device probe detects that the power
supply, voltage regulator module, or DC to DC
converter is pending a failure condition.
event=powerabsent Sets action or enables or disables alert generation
when a processor probe detects that the power supply
is absent.
event=powerfail Sets action or enables or disables alert generation
when a power device probe detects that the power
supply, voltage regulator module, or DC to DC
converter has failed.
event=processorwarn Sets action or enables or disables alert generation
when a processor probe detects that the processor is
running at less than peak performance or speed.
event=processorfail Sets action or enables or disables alert generation
when a processor probe detects that the processor has
failed.
Table 4-26. omconfig system platformevents
(continued)
Event Name Description